Dewpoint Transmitter CDT

Technical data:

  • Dimensions: Length: 170 mm | ø 82 mm
  • Power supply: 10-28 V DC
  • Mode: 2400 bps / 8 data bits / 1 stop bit; dew point and temperature
  • Cable length: max. 15 m
  • Measuring range: -80 / +20 °C dewpoint | -20 / +40 °C temperature
  • Accuracy: Dewpoint ± 1.0 °C at -70 °C < TP < +20 °C | Temperature ± 0.3 °C
  • Resolution: Dewpoint ± 1.0 °C at -70 °C < TP < +20 °C | Temperature ± 0.1 °C
  • Ambient temperature: -40 °C / +70 °C
  • Operating temperature: -20 °C / +40 °C
  • Operating pressure: max. 300 bar

 

> Brochure – PDF Download